Order No.Descriptionprice, Euro

 Transient recorder modules: 
TR 40-xx*Transient recorder, 12 bit-40 MHz A/D and 250 MHz photon counting acquisition, up to 0.4 ms signal length.8 600.-
TR 20-xx* Transient recorder, 12 bit-20 MHz A/D and 250 MHz photon counting acquisition, up to 0.8 ms signal length. 7 850.-
TR 20-xx*-AP Transient recorder with 2 separate inputs for 12 bit-20 MHz A/D and 250 MHz photon counting acquisition, allows simultaneous use of 2 detectors. 7 850.-
PR 20-160-P Photon Counting system, 250 MHz max. photon count rate, signal trace: 819 μs - 122km, two channels fit into one cassette. 5450.-
PR10-160-P Photon Counting system, 250 MHz max. photon count rate, signal trace: 1 838 μs - 244km, two channels fit into one cassette. 5450.-
 Options and Accessories: 
Trig-Las Optical trigger module for passive Q-switched laser 600.-
Cab-2 Data cable transient rack to interface card, shielded connectors with brackets, length 2 m. 180.-

 Rack and power supplies: 
Rack-1 Housing and power supply for single transient recorder. +5.4 V, -5 V, linear power supplies, data interface, AC 230 V-50 Hz / 110V-60 Hz input. 750.-
Rack-2 Housing and power supply for 2 transient recorders. AC 230 V-50 Hz / 110V-60 Hz input. 1 000.-
Rack-6 Housing and power supply for up to 6 transient recorders. AC 230 V-50 Hz / 110V-60 Hz input. 1 250.-
PMT-Rack3Rack for up to 3 pmt modules500.-
PMT-Rack8Rack for up to 8 pmt modules900.-

 Ethernet Remote Control 
Ethernet-int Ethermet interface module option for transient recorder rack. Control and readout of up to 16 transient recorders 700.-
PM-Remote-8 Ethernet interface for remote control of up to 8 photomultipliers. Remote high voltage setting and high voltage monitor. incl. LabView routines. Mounted in 3 HU cassette. 940.-
PM-Remote-4 Ethernet interface for remote control of up to 4 photomultipliers. Remote high voltage setting and high voltage monitor. incl. LabView routines. Mounted in 3 HU cassette. 890.-
APD-Remote-4 Ethernet interface for remote control of up to 4 APD modules. Remote high voltage setting and TEC on/off control. incl. LabView routines. Mounted in 3 HU cassette. 890.-
Trigger generator Ethernet interface for active laser flashlamp, Q-switch, Gating and transient recorder control. Variable repetition rate and pretrigger delay. Incl. LabView routines. Mounted in 3 HU cassette. 890.-
Laser Monitor Ethernet laser monitor. Continous acquisition of laser pulse energy measured by laser power meter (not. incl.) or photodiode (included). 1 350.-

 Detectors: 
Photomultiplier modules based on Hamamatsu mini PMT's, HV supply, stabilized dynodes, overcurrent protection, cables.
PM-HV-06160-650nm Bialkali2 500.-
PM-HV-03185-650nm Bialkali2 350.-
PM-HV-01185-600nm Multialkali2 650.-
PM-HV-02300-880nm Multialkali2 750.-
PM-HV-20300-900nm Multialkali3 050.-
PM-HV-SBA300-650nm Super Bialkali2 800.-
gatingoptional gating circuit for the PMT modules shown above. The gated PMT version can only be used in gated mode, max. gate ON time = 1msadd 850.-
Boresite 4-quadrant boresite alignment system, detector, photon counter, Ethernet interface 9 330.-
Sp32Multispectral Lidar detector, 32 Channel PMT17 000.-
Sp32-PowerExternal Power for Multispectral Lidar detector450.-
FiberFiber Bundel for Multispectral Lidar detector900.-
 
NIR (1064nm) enhanced Si-APDs for analog detection:
APD-0.8 Silicon APD detector module detector size 0.8 mm (dia.), responsitivity at 1060 nm typ. 34 A/W, peltier cooled, integrated preamplifier, 50 Ω output, integrated temperature control, HV supply (0...400V) and power supply. 5 500.-
APD-1.5 Silicon APD detector module detector size 1.5 mm (dia.), features as shown above. 5 700.-
APD-3.0 Silicon APD detector module detector size 3.0 mm (dia.), features as shown above. 6 900.-
Standard Si sensitivity APDs for analog or p.c. detection:
APD-C30902 Silicon APD detector module detector size 0.5 mm (dia.), not infrared enhanced, lower dark count rate 7 800.-
InGaAs APD module for eyesafe lidar
APD-InGaAs InGaAs APD detector module, 0.2mm dia., sens. 1100-1700 nm, air cooled, incl. AC/DC power supply, HV supply, focussing and alignment optics 7 800.-

Polarization measurements:
Polarotor Rotating polarizing beamsplitter for alternating measurements of parallel and perpendicular polarized signals up to 50Hz laser rep. rate. Ethernet interface. 8 900.-

 Software: 
Basic Drivers for LabView routines (source code) to perform data acquisitions, display signals, combine analog and photon counting signals, analyze photon counting pulse height distribution. Additional low level C-routines (NI-DAQ based) for integration into existing software.incl.
File Customized file format and naming convention according to local standards. 1 000.-
Develop LabView drivers for off-line software development, simulating hardware behaviour of transient recorders and lidar systems. 1 800.-

All Prices are EXW Berlin and excl. VAT and taxes


Back to index

Last update: 08.07.2008